The AR7200BX that came with my Blade helicopter is not supported in StudioX

AR7200BX with special Blade firmware on can't be programmed using StudioX as they are configured specificaly for the helicopter they are installed on. Nevertheless, you can update the firmware using StudioX and make a "full" AR7200BX out of it, so that it can be used with StudioX. But note that you’ll have to use the original AR7200BX manual to setup the device in future. A factory reset will NOT revert to the Blade preset then!

To keep your existing Blade settings it it important to update to firmware version 3.1.0 only, as this will not delete your setup. Once 3.1.0 is uploaded to the device, it will be recognized by StudioX and you can create restore points, change settings and more. So create a restore point of your device and then update to 4.0.14, if necessary. Updating to version 4.0.14 will reset your settings as 4.0.14 uses a new parameter set. But as you have created a restore point before, you can recover your setup and only have to setup the additional governor parameters.