==Electric drive system with rpm signal output from the speed controller==
+
==Elektroantrieb mit Drehzahlsignal vom Motorsteller==
When a speed controller is used that provides a rpm signal output you can directly plug the sensor wire from the ESC into the AX2/RPM input on the AR7210BX. In case the speed signal wire also has power lines watch our for correct polarity. The signal wire must be on top, the minus wire is connected at the bottom of the AR7210BX pin board. In case your speed controller doesn't come with power lines and only has one wire instead, make sure this wire is connected at the top of the device. The speed controller‘s control signal input is plugged into the throttle output [THRO] as usual.<br />
+
Wenn ein Motorsteller mit Signalleitung für das Drehzahlsignal verwendet wird (z.B. Castle EDGE, Hobbwing Platinum V4, YGE, ...), so kann diese Leitung direkt am Anschluss [AX2|RPM] am AR7210BX angesteckt werden. Falls dieses Leitung auch über einen Stromanschluss verfügt, achte unbedingt auf polungsrichtigen Anschluss. Das Kabel mit dem Drehzahlsignal muss ganz oben sein, Plus in der Mitte und Minus ist ganz unten auf der Stiftleiste des AR7210BX. Wenn die Signalleitung nur ein Kabel für das Signal hat, dann muss dieses am Anschluss AX2|RPM ganz oben sein. Das Kabel zur Ansteuerung des Motorsteller wird am Gasausgang [THRO] angesteckt.<br />
 