Changes

Jump to navigation Jump to search
no edit summary
Line 41: Line 41:  
==Startup== <!--T:17-->
 
==Startup== <!--T:17-->
   −
===AR7200BX/AR7210BX/AR7300BX does not finish initialization. What can I do?=== <!--T:43-->
+
===The SPEKTRUM AR7200BX / AR7210BX / AR7300BX does not finish initialization. What can I do?=== <!--T:43-->
Watch the running LED lights during the init phase: If the lights A - G light up the sensor's rest positions are beeing calibrated, H - N show determining the RC channels and their center positions.
+
Watch the running LED lights during the init phase: If the lights A - G light up the sensor's rest positions are beeing calibrated, H - N show determining the RC channels and their center positions.<br />
AR7200BX/AR7300BX: Initially the chase is from A - N. If one step is done the indication light for this step will quit running.
+
<br />
AR7210BX: Initially the chase is from H - N (Stick calibration). Only if this step is finished the chase from A - G (Sensor calibration) will start.
+
AR7200BX / AR7300BX: Initially the chase is from A - N. If one step is done the indication light for this step will quit running.<br />
 +
AR7210BX: Initially the chase is from H - N (Stick calibration). Only if this step is finished the chase from A - G (Sensor calibration) will start.<br />
    
<!--T:44-->
 
<!--T:44-->
Line 54: Line 55:  
<!--T:45-->
 
<!--T:45-->
 
When LEDs H - N do not quit running
 
When LEDs H - N do not quit running
* check whether your transmitter is correctly bound to the system.
+
* Is the transmitter switched on?
<br />
+
* Check whether your transmitter is correctly bound to the system.
 +
* Keep at least 1m/3ft distance between transmitter and receiver
 +
 
   −
===The brand new AR7200BX/AR7210BX/AR7300BX only shows a red flashing LED or even nothing. What's wrong?=== <!--T:47-->
+
===The brand new SPEKTRUM AR7200BX / AR7210BX / AR7300BX only shows a red flashing LED or even nothing. What's wrong?=== <!--T:47-->
    
<!--T:21-->
 
<!--T:21-->
Check very carefully whether all cables are plugged in correctly and all the plugs are connected properly at the correct position. Especially in the vertical direction, not just 2 pins must sit on the header. Also make sure that the polarity is correct on all connections.<br />
+
Check very carefully whether all cables are plugged in correctly and all the plugs are connected properly at the correct position. Especially in the vertical direction check that not just 2 pins sit on the header. Also make sure that the polarity is correct on all connections. Remove all servo connections to make sure that there is no defective servo pulling too much power.<br />
 
<br />
 
<br />
   Line 66: Line 69:     
===Can't access menus and also can't perform factory reset.=== <!--T:2-->
 
===Can't access menus and also can't perform factory reset.=== <!--T:2-->
''I am trying to access the menus but if I press the button either after powering on or before, the A light never goes solid or blinks. Also if I hold it for 10 seconds it doesn't appear to perform the factory reset.''
+
''I am trying to access the menus but if I press the button after powering on the A light never goes solid or blinks. Also if I hold it for 10 seconds it doesn't appear to perform the factory reset.''
    
<!--T:3-->
 
<!--T:3-->
To enter one of the menus you have to wait until the unit did perform the self test and did fully initialize: The Status LED must get blue or purple and the cycling LEDs A to G and H to N must have stopped.
+
To enter one of the menus you have to wait until the unit did perform the self test and did fully initialize: The Status LED must get blue or purple and the cycling LEDs A to G and H to N must have stopped.<br />
Factory reset only can be performed when being within Setup menu. So you have at least to get to Setup menu point '''A''' (or later), release the button and then push it and keep it pushed for at least 10 seconds. Note that factory reset will only revert all parameters of parameter menu and setup menu to default. It has no influence on receiver menu parameters. If the unit does not initialize due to wrong receiver setting the factory reset will not help. In such case also have a look here.<br />
+
<br />
 +
Factory reset only can be performed when being within Setup menu. So you have at least to get to Setup menu point '''A''' (or later), release the button and then push it and keep it pushed for at least 10 seconds. Note that factory reset will only revert all parameters of parameter menu and setup menu to default. If you can't get through initialization sequence either there is a problem with the sensors or some problem with the radio signal (see topics above). Doing a factory reset won't help here anyway!<br />
 
<br />
 
<br />
  
Bureaucrats, Administrators, translate-proofr
15,689

edits

Navigation menu