==StudioX does not recognize my device==
==StudioX doesn't recognize the BEASTX system using the USB2SYS serial interface (Windows/macOS)==
''I'm sure I have selected the correct interface port but StudioX scans for some time and than says no device found.''
* Make sure the wiring is connected correctly. The servo wire coming from the USB interface goes into SYS port on your BEASTX device. Watch out for correct polarity and '''make sure that the device is powered from a receiver battery or BEC''' (only when using the RX2SIM interface the BEASTX device can be powered from the USB port!).
* Make sure the wiring is connected correctly. The servo wire coming from the USB interface goes into SYS port on your MICROBEAST PLUS / AR7210BX. Watch out for correct polarity and '''make sure that the device is powered from a receiver battery or BEC''' (only when using the RX2SIM interface the BEASTX device can be powered from the USB port!).
* Using Windows check the port settings in Windows Device Manager (Press Start and type "Device Manger"). In Device Manager right click ''Silabs CP210x USB to UART'' which is the driver for the USB2SYS interface and choose ''Properties''. In ''Properties'' open the tab ''Port settings'' and make sure the settings are as shown below (115200 baud, 8, none, 1, none). Then click ''Advanced...'' and check FiFo settings. As shown here, you can optimize the serial connection by moving the sliders. Give it a try and test different settings. On our machines, all sliders are moved to the left but you may need different settings.<br />
* When using a smartphone the BLE2SYS interface must be connected to the SYS port, watch out for correct polarity. Make sure the LED on the BLE2SYS flashes in intervals of 2 seconds. By default the interface deactivates after 30 seconds whe there is no connection. In this case the LED is off. You have to cylce power in order to reactivate the device.
<br />
<br />
{|cellpadding="10"
|-
| [[File:Gerätemanager.PNG|border|none|x200px]]
| [[File:Anschlusseinstellungen.PNG|border|none|x200px]]
| [[File:Fifo.PNG|border|none|x200px]]
|}<br />
<br />
<br />

Latest revision as of 07:10, 21 August 2024

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Help:StudioX)
==StudioX doesn't recognize the BEASTX system using the USB2SYS serial interface (Windows/macOS)==
* Make sure the wiring is connected correctly. The servo wire coming from the USB interface goes into SYS port on your BEASTX device. Watch out for correct polarity and '''make sure that the device is powered from a receiver battery or BEC''' (only when using the RX2SIM interface the BEASTX device can be powered from the USB port!).
* Using Windows check the port settings in Windows Device Manager (Press Start and type "Device Manger"). In Device Manager right click ''Silabs CP210x USB to UART'' which is the driver for the USB2SYS interface and choose ''Properties''. In ''Properties'' open the tab ''Port settings'' and make sure the settings are as shown below (115200 baud, 8, none, 1, none). Then click ''Advanced...'' and check FiFo settings. As shown here, you can optimize the serial connection by moving the sliders. Give it a try and test different settings. On our machines, all sliders are moved to the left but you may need different settings.<br />
<br />
{|cellpadding="10"
|-
| [[File:Gerätemanager.PNG|border|none|x200px]]
| [[File:Anschlusseinstellungen.PNG|border|none|x200px]]
| [[File:Fifo.PNG|border|none|x200px]] 
|}<br />
<br />

StudioX doesn't recognize the BEASTX system using the USB2SYS serial interface (Windows/macOS)

  • Make sure the wiring is connected correctly. The servo wire coming from the USB interface goes into SYS port on your BEASTX device. Watch out for correct polarity and make sure that the device is powered from a receiver battery or BEC (only when using the RX2SIM interface the BEASTX device can be powered from the USB port!).
  • Using Windows check the port settings in Windows Device Manager (Press Start and type "Device Manger"). In Device Manager right click Silabs CP210x USB to UART which is the driver for the USB2SYS interface and choose Properties. In Properties open the tab Port settings and make sure the settings are as shown below (115200 baud, 8, none, 1, none). Then click Advanced... and check FiFo settings. As shown here, you can optimize the serial connection by moving the sliders. Give it a try and test different settings. On our machines, all sliders are moved to the left but you may need different settings.