Translations:Manuals:MB Plus:Governormenu D/2/de: Difference between revisions

From BEASTX Wiki
Jump to navigation Jump to search
Created page with "===Drehzahlregler im Modus Elektro=== Im Modus '''Elektro''' wird der Motorsteller nicht mehr vom Piloten über den Fernsteuersender kontrolliert, sondern MICROBEAST PLUS übe..."
 
No edit summary
Line 14: Line 14:
<br />
<br />
{|style="text-align:center; margin:0px 0px 0px 480px" cellpadding="4" cellspacing="0" border="1"
{|style="text-align:center; margin:0px 0px 0px 480px" cellpadding="4" cellspacing="0" border="1"
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
!colspan="2"  | Gasposition<br />(Einteilung abhängig vom Senderfabrikat)
!style="width:100px;" | <br />Rotordrehzahl
!style="width:100px;" | <br />Rotordrehzahl
!<br />Status LED
!<br />Status LED

Revision as of 08:23, 16 June 2015

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Manuals:MB Plus:Governormenu D)
===Electric Governor===
In '''electric''' governor mode the pilot does no longer control the speed controller with the transmitter. MICROBEAST PLUS completely takes over control of the ESC. With the transmitter you only specifiy the desired rotor rpm you want the helicopter to maintain. When setting a rpm higher than zero, MICROBEAST PLUS will speed up the rotor smoothly and ensure that the demanded rotor rpm is kept constant throughout the flight. To practice autorotation landings, additionaly you can keep MICROBEAST PLUS in a special mode that causes the speed controller to be switched off during the maneuver but speed up the rotor rpm fast when aborting the autorotation (faster than with the initial soft start).<br />
<br />
The rotor rpm is set via the throttle channel of the transmitter. You may use the transmitter‘s throttle curves for instance, so you can switch the motor on and off and pretend different speeds using the flight mode system of the transmitter. Instead of curves you only have to set horizontal lines so that the rotor rpm value does not depend on the throttle stick position but is fixed in each flight mode. The flight mode switch then acts as a switch that switches between different speed settings.<br />
<br />
<gallery mode="nolines" widths="300" heights="127">
File:EGov_normal_fm.png
File:EGov_idleup_1.png
File:EGov_idleup_2.png
File:EGov_hold.png
</gallery>
<br />
In '''electric''' mode the adjustable throttle range is 3400 rpm/min. The lowest rotor speed that can be set is 600rpm/min, the maximum speed is 4000rpm/min. To enable autorotation bail out mode the throttle must be set to a value between 5% and 15%.<br />
<br />
{|style="text-align:center; margin:0px 0px 0px 480px" cellpadding="4" cellspacing="0" border="1"
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
!style="width:100px;" | <br />Rotor rpm
!<br />Status-LED
|-
| 100% || +100 || 4000
|style="background-color:#CC66CC; color:white" | '''purple'''
|-
| 95% || +90 || 3800
| rowspan="17" style="background-color:#FF3300; color:white" | '''red'''
|-
| 90% || +80 || 3600
|-
| 85% || +70 || 3400
|-
| 80% || +60 || 3200
|-
| 75% || +50 || 3000
|-
| 70% || +40 || 2800
|-
| 65% || +30 || 2600
|-
| 60% || +20 || 2400
|-
| 55% || +10 || 2200
|-
| 50% || 0 || 2000
|-
| 45% || -10 || 1800
|-
| 40% || -20 || 1600
|-
| 35% || -30 || 1400
|-
| 30% || -40 || 1200
|-
| 25% || -50 || 1000
|-
| 20% || -60 || 800
|-
| 15% || -70 || 600
|-
| 10% || -80
| rowspan="2" | Motor off/<br />Autorotation
| rowspan="2" style="background-color:#0066FF; color:white" | '''blue'''
|-
|  5% || -90
|-
|  0% || -100 || Motor off
|style="background-color:black; color:white" | '''off'''
|}<br />
<br />

Drehzahlregler im Modus Elektro

Im Modus Elektro wird der Motorsteller nicht mehr vom Piloten über den Fernsteuersender kontrolliert, sondern MICROBEAST PLUS übernimmt die Ansteuerung des Motorstellers. Mit dem Fernsteuersender wird nur noch die gewünschte Drehzahl vorgegeben. Der Drehzahlregler von MICROBEAST PLUS lässt den Motor sanft hochlaufen und sorgt dafür, dass die Drehzahl über den ganzen Flug hinweg konstant gehalten wird. Um Autorotationen zu üben kann der Drehzahlregler in eine speziellen Betriebsmodus geschaltet werden, in dem der Motor ausgeschaltet wird und bei Abbruch der Autorotation sofort wieder hochgefahren wird, also schneller als mit dem anfänglichen Sanftanlauf.

Die Einstellung der Drehzahlvorgabe erfolgt über den Gaskanal vom Fernsteuersender. Verwenden Sie z.B. die Gaskurven im Fernsteuersender in Verbindung mit einer Flugphasenumschaltung, um den Motor ein- und auszuschalten und um verschiedene Drehzahlen vorzugeben. Anstatt von Gaskurven werden aber nur waagerechte Geraden programmiert, so dass der Gaswert nicht mehr von der Gasknüppelstellung abhängt sondern in der jeweiligen Flugphase fest ist. Die Flugphasenumschaltung wirkt dann wie ein Schalter, der zwischen verschiedenen Drehzahlvorgaben umschaltet.


Im Modus Elektro beträgt der regelbare Gasbereich 3400 Umdrehungen/Minute. Der Motor wird ab einem Gaswert von 15% eingeschaltet. Die niedrigste einstellbare Rotorkopfdrehzahl beträgt 600 Umdrehungen/Minute. Bei 100% Gaswert wird die maximale Rotorkopfdrehzahl auf 4000 Umdrehungen/Minute eingeregelt (soweit möglich). Für den Autorotationsmodus muss ein Gaswert zwischen 5% und 15% anliegen.

Gasposition
(Einteilung abhängig vom Senderfabrikat)

Rotordrehzahl

Status LED
100% +100 4000 violett
95% +90 3800 rot
90% +80 3600
85% +70 3400
80% +60 3200
75% +50 3000
70% +40 2800
65% +30 2600
60% +20 2400
55% +10 2200
50% 0 2000
45% -10 1800
40% -20 1600
35% -30 1400
30% -40 1200
25% -50 1000
20% -60 800
15% -70 600
10% -80 Motor aus/
Autorotation
blau
5% -90
0% -100 Motor aus aus