==Slow rampup speed (J)==
+
==Geschwindigkeit Sanftanlauf (Punkt J)==
When using the internal Governor function this will not apply full throttle immediately when switching into idle up but will increase the motor speed slowly until the desired head speed is reached. At menu point J you can determine how fast this soft start occurs when the Governor is activated initially. The speed is given in number of revolutions by how much the rotor speed is increased per second. The higher the speed the faster your preset head speed will be reached. Please note that the given rates only are indicative. Depending on the response of the speed controller and the inertia of the rotor system it can actually take longer or shorter until the desired speed is reached.<br />
+
Beim Aktivieren der Drehzahlregelung gibt das System nicht schlagartig Gas, sondern fährt die
 +
Rotorkopfdrehzahl langsam hoch bis die gewünschte Vorgabedrehzahl erreicht ist. Der Parameter bei
 +
Einstellpunkt J bestimmt, wie schnell dieser Sanftanlauf beim erstmaligen Einschalten des
 +
Drehzahlreglers stattfindet. Die Geschwindigkeit wird dabei angegeben in Umdrehungen, um wieviel die
 +
Rotordrehzahl pro Sekunde erhöht wird. Je höher die Geschwindigkeit, umso eher ist die Vorgabedrehzahl
 +
erreicht. Beachten Sie, dass die angegebenen Geschwindigkeiten nur Richtwerte darstellen. Abhängig
 +
vom Ansprechverhalten des Motorstellers und der Trägheit des Rotorsystems, kann es tatsächlich länger oder auch kürzer dauern, bis die gewünschte Drehzahl erreicht ist.<br />
 
<br />
 
<br />
{{TABLEV5|Slow rampup speed
+
{{TABLEV5/de|Geschwindigkeit Sanftanlauf
|50 rps
+
|50 U/s
|100 rps
+
|100 U/s
 
|200 rps
 
|200 rps
|300 rps
+
|300 U/s
|400 rps
+
|400 U/s
 
}}<br />
 
}}<br />
 
<br />
 
<br />
With the StudioX software/StudioXm App you have the option to disable the softstart feature, which will set the spool up rate to "0". This is necessary when using a speed controler with built-in softstart feature (but without headspeed governing!). In this case the system will add half throttle immediately and wait until the speed controler has finished the spool up. Then it will activate the governing.<br />
+
Mit der StudioX Software/StudioXm App kann der Sanftanlauf deaktiviert werden, dabei wird der Wert auf 0 gesetzt "0". Das ist nötig, wenn der Motorsteller bei einem Elektroheli über einen eigenen Sanftanlauf verfügt  (aber keine Governor-/Drehzahlregelfunktion hat!). Hier wird der AR7210BX Empfänger beim einschalten des Motors sofort Halbgas geben und warten, bis der Motorsteller die Drehzahl soweit hochgefahren hat. Dann wird er in den Drehzahlregelmodus umschalten.<br />
 
<br />
 
<br />
{{WARNING_QUOTE|Please note that you can't set a speed lower than 50 rps with StudioX because of the fact noted above. Setting the speed below 50 will be the same as setting it to 0, so it will disable the soft start!}}<br />
+
{{WARNING_QUOTE|Bitte beachte, dass aus dem oben genannten Grund die Anlaufgeschwindigkeit über StudioX nicht langsamer als 50 U/s eingestellt werden kann. Werte unter 50 haben dieselbe Wirkung wie der Wert 0, der Sanftanlauf ist dann also deaktiviert!}}<br />
 
<br />
 
<br />
   −
==Fast rampup speed (K)==
+
==Änderungsgeschwindigkeit (Punkt K)==
When using the internal governor function and you change the head speed in the transmitter in flight (i.e. by switching to a different flight mode), there will not be an abrupt change but the system will increase the rotor rpm with a given rate that can be adjusted here. This rate also determines how fast the rotor head speed will increase when reactivating the Governor after an autorotation maneuver (Autorotation bailout). In this case, when the heli is still in the air, the normal soft start (which is set at point J) would take way too much time for the rotor to speed up again, so we use this faster spool up rate instead.<br />
+
Wenn der Drehzahlregler aktiv ist und von einer niedrigeren in eine höhere Drehzahlvorwahl geschaltet
 +
wird (z.B. durch wechsel der Flugphase), wird die Drehzahl schrittweise erhöht. Wie schnell das passiert, wird bei Einstellpunkt K gesondert vorgegeben werden, weil der normale Sanftanlauf von Punkt I vermutlich zu langsam sein wird. Die Einstellung bei Punkt K bestimmt ausserdem, wie schnell die Drehzahl nach Abbruch eines Autorotationsmanövers wieder
 +
hochgefahren wird, da auch hier die Geschwindigkeit des Sanftanlaufs in möglicherweise zu langsam
 +
sein wird.<br />
 
<br />
 
<br />
{{TABLEV5|Fast rampup speed
+
{{TABLEV5/de|Änderungsgeschwindigkeit
|same as slow rampup speed (J)
+
|wie Sanftanlauf (Punkt J)
|300 rps
+
|300 U/s
|500 rps
+
|500 U/s
|700 rps
+
|700 U/s
|900 rps
+
|900 U/s
 
}}<br />
 
}}<br />
 
<br />
 
<br />
{{WARNING_QUOTE|When using a very fast rampup speed in consequence the throttle will be opened very quick. Especially when recovering from an autorotation maneuver this can cause the rotor blades to fold in or will damage the main gear. So only increase the value stepwise and with care. With nitro helicopters using quite low values is recommended (even the setting "same as slow rampup speed (J)" may be sufficient) as here an abrupt throttle change from idle position can cause the engine to quit! Also nitro motors react quite slow to throttle changes and it takes some time to speed up the rotor. When the change rate does not fit to the physical speed up, it can happen that the motor is driven to full throttle during spool up by accident as the motor does not come to speed. In this case for technical reason it may happen that the systems stays at full throttle then!}}<br />
+
{{WARNING_QUOTE|Eine zu hoch gewählte Geschwindigkeit kann dazu führen, dass das Gas sehr schnell geöffnet
 +
wird. In Folge können die Rotorblätter anklappen, wenn sie nicht fest genug angezogen wurden, oder das
 +
Hauptgetriebe kann beschädigt werden. Bei Verbrennermodellen sollte grundsätzlich eine eher niedrige
 +
Einstellung verwendet werden, evtl. sogar die Einstellung „wie Sanftanlauf“, da hier eine zu abrupte
 +
Gasänderung dazu führen kann, dass der Motor aus geht. Ausserdem kann es passieren , dass wegen der Rotorträgheit und der Entkopplung von Motor und Rotor über die Kupplung, die Drossel teils bis zur Vollgasposition geöffnet wird, lange bevor die Zieldrehzahl erreicht wird. Das kann zu dem Effekt führen, dass das Gas letztlich auf Vollgas hängen bleibt, selbst wenn die Zieldrehzahl irgendwann erreicht wird!}}<br />
 