Changes

Jump to navigation Jump to search
no edit summary
Line 28: Line 28:  
In '''electric''' mode the adjustable throttle range is 4200 rpm/min. The lowest rotor speed that can be set is 800rpm/min, the maximum speed is 5000rpm/min. To enable autorotation bail out mode the throttle must be set to a value between 5% and 15%.<br />
 
In '''electric''' mode the adjustable throttle range is 4200 rpm/min. The lowest rotor speed that can be set is 800rpm/min, the maximum speed is 5000rpm/min. To enable autorotation bail out mode the throttle must be set to a value between 5% and 15%.<br />
 
<br />
 
<br />
{|style="text-align:center; margin:0px 0px 0px 480px" cellpadding="4" cellspacing="0" border="1"
+
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px;" cellpadding="4" cellspacing="0" border="1"
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
 
!style="width:100px;" | <br />Rotor rpm
 
!style="width:100px;" | <br />Rotor rpm
Line 34: Line 34:  
|-
 
|-
 
| 100% || +100 || 5000
 
| 100% || +100 || 5000
|style="background-color:#CC66CC; color:white" | '''purple'''
+
| style="background-color:#0066FF; color:white" | '''blue'''
 
|-
 
|-
 
| 95% || +90 || 4750
 
| 95% || +90 || 4750
Line 73: Line 73:  
| 10% || -80
 
| 10% || -80
 
| rowspan="2" | Motor off/<br />Autorotation
 
| rowspan="2" | Motor off/<br />Autorotation
| rowspan="2" style="background-color:#0066FF; color:white" | '''blue'''
+
| rowspan="2" style="background-color:#CC66CC; color:white" | '''purple'''
 
|-
 
|-
 
|  5% || -90
 
|  5% || -90
Line 95: Line 95:  
</gallery>
 
</gallery>
 
<br />
 
<br />
{|style="text-align:center; margin:0px 20px 0px 360px; float:left" cellpadding="4" cellspacing="0" border="1"
+
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px; float: left;" cellpadding="4" cellspacing="0" border="1"
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
!style="width:100px;" |
+
!style="width: 150px;" | <br />Status-LED
 
|-
 
|-
 
| 100% || +100
 
| 100% || +100
|  rowspan="16" | Manual control/<br /><div style="color:#FF3300">RPM control</div>
+
|  rowspan="16" | '''off'''<br />(= Manual control)<br /><br /><span style="color:#FF3300">'''red'''</span> or <span style="color:#0066FF">'''blue'''</span><br />(= RPM control)
 
|-
 
|-
 
| 95% || +90
 
| 95% || +90
Line 133: Line 133:  
|-
 
|-
 
| 20% || -60
 
| 20% || -60
|  rowspan="5" | Manual control/<br /><div style="color:#0066FF">Autorotation</div>
+
|  rowspan="5" | '''Manual control'''/<br /><div style="color:#CC66CC">'''Autorotation'''</div>
 
|-
 
|-
 
| 15% || -70
 
| 15% || -70
Line 145: Line 145:     
<!--T:4-->
 
<!--T:4-->
{|style="text-align:center; float:left" cellpadding="4" cellspacing="0" border="1"
+
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px;" cellpadding="4" cellspacing="0" border="1"
 
!style="width:100px;" | <br />Rotor rpm
 
!style="width:100px;" | <br />Rotor rpm
!style="width:150px;" |Governor<br />channel
+
!style="width:150px;" | <br />Governor channel
 
|-
 
|-
 
|3000 || +100
 
|3000 || +100
Line 189: Line 189:  
|500|| -90
 
|500|| -90
 
|-
 
|-
|aus || -100
+
|off || -100
 
|}
 
|}
 
<div style="clear:both">
 
<div style="clear:both">
Line 208: Line 208:  
<br />
 
<br />
 
<br />
 
<br />
{|style="text-align:center; margin:0px 0px 0px 180px" cellpadding="4" cellspacing="0" border="1"
+
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px;" cellpadding="4" cellspacing="0" border="1"
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
 
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
 
!style="width:100px;" | <br />Rotor rpm
 
!style="width:100px;" | <br />Rotor rpm
Line 214: Line 214:  
|-
 
|-
 
| 100% || +100 || 3000
 
| 100% || +100 || 3000
|style="background-color:#CC66CC; color:white" | '''purple'''
+
|style="background-color:#0066FF; color:white" | '''blue'''
 
|-
 
|-
 
| 95% || +90 || 2750
 
| 95% || +90 || 2750
Line 238: Line 238:  
|-
 
|-
 
| 45% || -10
 
| 45% || -10
| rowspan="2" | Manual control/<br />Autorotation
+
| rowspan="2" | Manual control or Autorotation
| rowspan="2" style="background-color:#0066FF; color:white" | '''blue'''
+
| rowspan="2" style="background-color:#CC66CC; color:white" | '''purple'''
 
|-
 
|-
 
| 40% || -20
 
| 40% || -20
Bureaucrats, Administrators, translate-proofr
15,683

edits

Navigation menu