Changes

Jump to navigation Jump to search
Created page with "== Verbrennerheli - Drehzahlregelung über Zusatzkanal == Im '''Verbrennerheli''' kann das Gas bzw. das Gasservo grundsätzlich voll über den Gaskanal der Fernsteuerung anges..."
Line 79: Line 79:  
<br />
 
<br />
   −
==Nitro Governor - with separate control channel==
+
== Verbrennerheli - Drehzahlregelung über Zusatzkanal ==
When the '''nitro''' Governor mode is used, the throttle servo can be controlled entirely via the throttle channel of the remote control as long as the RPM Governor is switched off. This is especially necessary to start and warm up the engine as well as to stop the engine after the flight. Only when the RPM Governor is switched on, the system will take over control of the throttle servo to spool up the rotor to the desired speed (if this is not yet reached) and ensure that the rotor speed is maintained during the flight. As some model engines react very sensitive in the lower throttle sector and abrupt engagement can cause the engine to quit, i.e. when the clutch is not fully engaged and/or the rotor is not yet turning, also the manual throttle control can be of advantage. The pilot can run the engine to speed "by hand" before control is passed over to the RPM Governor.<br />
+
Im '''Verbrennerheli''' kann das Gas bzw. das Gasservo grundsätzlich voll über den Gaskanal der Fernsteuerung angesteuert werden. Dies ist vor allem wichtig zum Anlassen des Motors und um den Motor warmlaufen lassen zu können, sowie auch zum Ausschalten des Motors. Ausserdem reagieren manche Modellmotoren im unteren Gasbereich sehr empfindlich und ein zu abruptes Einkuppeln kann dazu führen, dass der Motor beim Starten ausgeht. In diesem Fall ist eine manuelle Gassteuerung ebenfalls vorteilhaft und der Pilot kann den Motor erst einmal von Hand hochlaufen lassen, bevor die Kontrolle an den Drehzahlregler übergeben wird. Erst wenn der Drehzahlregler zugeschaltet wird, übernimmt dieser die Kontrolle über das Servo, fährt den Rotor auf die gewünschte Drehzahl hoch (falls diese noch nicht erreicht ist) und sorgt dafür, dass die Rotordrehzahl während des Flugs entsprechend gehalten wird. <br />
 
<br />
 
<br />
Depending on whether an auxiliary channel was assigned to control the RPM Governor in Receiver setup menu or not, the RPM Governor is either controlled separately via this channel or you can control both RPM Governor and throttle servo alone by using the throttle channel of the transmitter. In general the adjustable throttle range in „nitro“ mode is 2500 rpm/min. The lowest head speed to govern is 500 rpm/min, the maximum head speed is 3000 rpm/min.<br />
+
Die niedrigste wählbare Rotordrehzahl beträgt 500U/min, die Maximaldrehzahl liegt bei 3000U/min.<br />
 
<br />
 
<br />
If a separate control channel is used for the RPM Governor the throttle servo can be controlled as usual via throttle channel and throttle curves of the transmitter. By switching the separate control channel in different positions, the RPM Governor can be activated and the desired rotor rpm can be preset. Note that for safety reason the throttle channel has priority over the RPM Governor when  the output is below 25%. So you can always control the lower throttle servo positions by hand, even if the RPM Governor is already switched on. Then when the throttle is raised above 25% the RPM Governor intervenes and spools up the rotor. Also when you want to bring the throttle servo to idle position for autorotation or to shut off the engine you can always do this, regardsless of how the RPM Governor is switched. Anyhow keep in mind that MICROBEAST PLUS will be set to autorotation bail out mode if the RPM Governor is switched on and the throttle channel is brought below 25%. When throttle then is increased again, the RPM Governor will speed up the rotor faster than on initial spool up! Therefore if you make a stopover and the rotor is completely stopped, the RPM Governor must be completely disabled once by using the separate control channel. So the RPM Governor is reset and will perform an initial startup again. Otherwise if autorotation  mode would still be active, the helicopter may tip over due to the abrupt speed up (this does not apply if you set the bail out spool up rate at [[Manuals:MB_Plus:Parametermenu_K/en|Parameter menu point '''K''']] as high as the initial spool up rate).<br />
+
Aus Sicherheitsgründen hat der Gaskanal Priorität vor der Drehzahlregelung wenn der die Höhe des Gaskanal unter 25% liegt. In diesem Bereich kann das Gasservo immer manuell gesteuert werden, egal welchen Wert der Kanal für die Drehzahlregelung hat. So kann z.B. der Motor angelassen werden, selbst wenn die Drehzahlregelung schon über den Schalter aktiviert ist, oder der Motor unabhängig vom Drehzahlregler abgestellt werden. Erst wenn der Gaskanal einen Wert höher als 25% hat, ist die Position des Kanals für die Drehzahlregelung massgeblich und der Drehzahlregler wird entsprechend aktiviert und bringt den Rotor ggf. auf Touren. Zu beachten ist hier weiter, dass die Drehzahlregelung in den Modus Autorotation geschaltet wird, wenn die Drehzahlregelung einmal aktiv war und das Gas auf eine Position tiefer als 25% gebracht wird. D.h. wenn das Gas wieder erhöht wird, bringt der Drehzahlregler den Rotor  sofort wieder auf Touren, viel schneller als beim anfänglichen Sanftanlauf. Wenn also eine Zwischenlandung gemacht wird und der Rotor vollständig steht, so muss der Drehzahlregler erst komplett deaktiviert werden, damit der Regler beim erneuten Einschalten die Drehzahl wieder sanft hochfährt. Andernfalls würde der Schnellhochlauf starten und der Helikopter könnte durch das abrupte Gasgeben umkippen.<br />
 
<br />
 
<br />
 
<gallery mode="nolines" widths="400" heights="200">
 
<gallery mode="nolines" widths="400" heights="200">
Line 93: Line 93:  
<br />
 
<br />
 
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px; float: left;" cellpadding="4" cellspacing="0" border="1"
 
{|style="text-align:center; font-size: 80%; margin:0px 20px 0px 0px; float: left;" cellpadding="4" cellspacing="0" border="1"
!colspan="2"  | Throttle position<br />(scale depending on transmitter)
+
!colspan="2"  | Gasposition<br />(Bezeichnung Senderabhängig)
 
!style="width: 150px;" | <br />Status-LED
 
!style="width: 150px;" | <br />Status-LED
 
|-
 
|-
 
| 100% || +100
 
| 100% || +100
|  rowspan="16" | '''off'''<br />(= Manual control)<br /><br /><span style="color:#FF3300">'''red'''</span> or <span style="color:#0066FF">'''blue'''</span><br />(= RPM control)
+
|  rowspan="16" | '''aus'''<br />(= Manuelle Kontrolle)<br /><br /><span style="color:#FF3300">'''rot'''</span> oder <span style="color:#0066FF">'''blau'''</span><br />(= Drehzahlregelung)
 
|-
 
|-
 
| 95% || +90
 
| 95% || +90
Line 130: Line 130:  
|-
 
|-
 
| 20% || -60
 
| 20% || -60
|  rowspan="5" | '''Manual control'''/<br /><div style="color:#CC66CC">'''Autorotation'''</div>
+
|  rowspan="5" | '''Manuelle Kontrolle'''/<br /><div style="color:#CC66CC">'''Autorotation'''</div>
 
|-
 
|-
 
| 15% || -70
 
| 15% || -70
Bureaucrats, Administrators, translate-proofr
15,511

edits

Navigation menu